PSC PowerScanTM RF Specifikace Strana 57

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 88
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 56
Systems Manual
53
Transmission
Retries Before
Message Time-
out
When the scanner attempts to transmit data to the Base Station, com-
munication may not always occur on the first try due to interference,
signals from other scanners in the queue, etc.. This setting defines the
number of transmission retries the scanner/Base Station will attempt
before the message gives up tryng to successfully resend/transmit the
message (times out). If the specified retry count is exceeded, the scan-
ner will sound a transmission error beep (when transmission error
beep is enabled).
In a noisy RF environment, a large number of retries may allow a trans-
mission to get through to the Base Station, but at the cost of increased
time-out (should the transmission fail). To maximize battery life, set
this feature to the lowest optimal number of retries.
Selectable range for this setting is 0-15 retries.
Feature is applicable to scanner
and
Base Station.
NOTE
Remember, programming changes to the Base Sta-
tion have no effect until the new configuration is
downloaded via the feature
Transmit Scanner Con-
figuration to Base Station
on page 33.
SET -------------------------------------------
0 Retries ---------
1 Retry ---------
Zobrazit stránku 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 87 88

Komentáře k této Příručce

Žádné komentáře