Product Reference Guide A-5
Scale Zero Push Button
The Scale Zero Push Button is used for multiple functions as listed in
Table A- 3.
Table A-3. Scale Zero Push Button Functions
Calibration Switch
This switch initiates the scales calibration routine. A certified weight set is
needed to perform the scale calibration steps detailed in Section 5, Cali-
bration. This switch is not included in scanners without scale modules.
NOTE
The Scale Zero Push Button has no function in a “scanner only” model.
PRESS
DURATION
FUNCTION COMMENT
Momentary Zero Scale
When programmed to do so, the yellow LED should be lit when no
weight is on the scale, indicating scale at zero. If it is not, press the
switch to zero the scale. The unit will sound a “click” upon pressing
the button.
4 Seconds
Scale Diagnostics
Mode
a
This mode allows system support personnel to troubleshoot prob-
lems with the scale. Momentarily press the Scale Zero Push Button
or cycle power to exit Scale Diagnostics Mode.
a. Diagnostics Mode is meant for use by trained systems support personnel. Users should not need to ini-
tiate this function under normal circumstances.