Configuration Utility
< 2-34 > PowerNet Twin Client User Guide
Load New Configuration
After creating and saving the PowerNet Twin Client configuration, load
the new configuration to the terminal.
Complete the following steps to load a new PowerNet Twin Client
configuration:
1. Perform a safe-boot of the terminal.
w
ww
w For Falcon 315 and 325: Press <CTL><ALT><DEL>. When
the “Wait...” message appears, press
<ESC><DEL>.
w
ww
w For Falcon 335: Press <CTL><ALT><DEL>. When the
“Wait...” message appears, press
<ESC><SPACE>.
w
ww
w For Falcon 615/655 (6x5): Press <F5> at the starting MS-
DOS
prompt.
w
ww
w For Falcon 3xx only: The terminal will emit a low tone
followed by a higher pitched tone if the safe-boot is successful.
2. Select
Send Setup Files to Terminal from the Terminal menu
in the PowerNet Twin Client Windows configuration utility.
3. Typ e
LD at a c:\ prompt on the Falcon and press the ENTER.
w
ww
w If the terminal currently has PowerNet Twin Client running,
press the
<F10> key on the terminal to terminate the current
session.
w
ww
w Falcon 315 Only: When the “Any Key to Continue” message
appears, press
<ALPHA><CAPS><C> and select Exit; this
will return the
c:\ prompt.
4. From the PC, select the
OK button after confirming that the LD
on the terminal has started.
5. From the PC, select the
OK button after receiving the “Tr a n s f e r
Complete” message.
6. Perform a safe-boot as presented in step 1.